1,General speed of box type high temperature furnace
This series of box-type atmosphere furnace are periodic operation type, using double shell structure and 30 sections of program temperature control system, phase-shift trigger, silicon control, furnace using alumina polycrystalline fiber 1750 material, the double-layer furnace shell is equipped with an air cooling system, which can quickly cool down. The furnace has the advantages of balanced temperature field, low surface temperature, fast temperature rise and fall, energy saving, etc. . It is used for quenching and annealing in universities, scientific research institutions, and industrial and mining enterprises, for heating when tempering. Can also metal, ceramic sintering, dissolution, analysis and other high-temperature heating with sintering, ideal products.
2,Technical parameters of MFX1200-30 box type high temperature furnace
| Project |
Unit |
Index value |
| Box Furnace |
Model |
MFX1400-30 |
| Furnace structure |
|
Double shell structure with air cooling system |
| Rated power |
KW |
15 kilowatts |
| Rated voltage |
V |
380VAC |
| Frequency |
Hz |
50/60 |
| Phase number |
|
Three phases |
| Maximum temperature |
℃ |
1350 |
| Temperature in common use |
℃ |
1300 |
| Heating rate |
°C/min |
≤10 |
| The heating rate is recommended |
℃/min °C/min |
5-8 5-8 |
| Furnace dimensions |
Mm |
500 x 400 x 400 |
| Instrument manufacturers |
|
Muffle technology |
| Accuracy of temperature control |
℃ |
+1 + 1 |
| Temperature control |
|
50-segment program temperature PID adjustment, silicon control can be controlled |
| Type of thermocouple |
Indexing |
S |
| Heating element |
|
Silicon carbide rod |
| Furnace materials |
|
Type 1750 alumina-silica polycrystalline fiber < alumina content above 90% > |
| Weight |
KG KG |
300 |
| Furnace surface temperature |
℃ |
≤60 ≤60 |
3,Introduction to structure
The chamber is a vacuum-formed alumina fiber furnace. The heating elements are placed in the furnace, and the bottom of the furnace is equipped with an alumina furnace bottom plate. Between the furnace and the furnace shell, the 1750 type fiber board is filled, and the double-layer shell structure is adopted, integrated design of temperature control system and furnace body.
The equipment is a series of high temperature electric furnace, need to have strict technical requirements.
4,drying furnace process
The electric furnace should be dried before use. The steps are as follows:
- 0 °C-300 °C 1H heating
- 300 °C-300 °C for 3 H
- 300 °C-600 °C for 1 H
- 600 °C-600 °C for 3 H
- Electric Furnace Idle for more than half a year should be used again according to the above process oven;
5, the installation of equipment wiring
- Box-type atmosphere furnace must be installed in the horizontal electric non-vibration platform, away from explosive gases and materials;
- The furnace terminal should be connected to the air switch, power three-phase 380ACV connection, terminal L1. L2. L 3 connect the fire wire on the power supply, n connect the zero wire, ⊥ ground wire.
MFX1400-30 series high temperature box furnace users to be equipped with 80A air switch or circuit breaker.
6,Equipment operation
When the line is connected, check whether the line is correct
Turn on the air switch
Push-button SWITCH to see if the temperature gauge is displayed
- Put the material into the furnace, using the crucible pliers to put the material in the middle position;
Plug the brick of the furnace door, close the furnace door and tighten the screw of the furnace door;
- Set the instrument, (other parameters of the instrument have been set before leaving the factory, the user only needs to set the temperature of the product
- Instrument operation and matters needing attention
7, instrument detailed operation, please contact the technical department.
1, the instrument features:
- A, automatic PID control, in low temperature, medium temperature, high temperature precision control;
- B, the instrument has the function of broken couple protection, the instrument automatically stops running after broken couple;
- C, the instrument can view the current running program section and the running time of the section;
- D. the instrument has self-tuning and over-temperature protection functions
- E, the instrument has the function of automatic shutdown;
- F, cop key into the U disk, click on this key will be the instrument in the data stored in the U disk;
2, heating, constant temperature, cooling reference curve:

8,Specifications:
| MFX series, box type high temperature furnace |
| Type of equipment |
Heating specs |
Maximum temperature |
Long-term use |
Power |
Voltage |
Heating element |
Temperature measuring element |
| MFX1100-10 |
100 * 100 * 100 |
1100 °C |
1000 °C |
1 kw |
Single-phase 220V |
Resistance wire |
Type K |
| MFX1200-20 |
200 * 120 * 80 |
1200 °C |
1100 °C |
1.5 kw |
Single-phase 220V |
Resistance wire |
Type K |
| MFX1200-30A |
300*200*120 |
1200 °C |
1100 °C |
3KW |
Single-phase 220V |
Resistance wire |
Type K |
| MFX1200-30 |
300*200*200 |
1200 °C |
1100 °C |
4KW |
Single-phase 22OV |
Resistance wire |
Type K |
| MFX1200-40 |
400*300*300 |
1200 °C |
1100 °C |
9 kw |
Three-phase 380V |
Resistance wire |
Type K |
| MFX1200-50 |
500*400*400 |
1200 °C |
1100 °C |
15 kw |
Three-phase 380V |
Resistance wire |
Type K |
MFX1200-60 Mfx1200-60 |
600*600*600 600 * 600 * 600 |
1200℃ 1200 °C |
1100℃ 1100 °C |
40kw 40 kw |
三相380v Three-phase 380V |
硅碳棒 Silicon carbide rod |
K型 Type K |
MFX1400-15 MFX1400-15 |
150*150*150 150 * 150 * 150 |
1200℃ 1200 °C |
1300℃ 1300 °C |
4kw 4KW |
单相220v Single-phase 220V |
硅碳棒 Silicon carbide rod |
S型 Type S |
MFX1400-30 MFX1400-30 |
300*200*200 300 * 200 * 200 |
1400℃ 1400 °C |
1300℃ 1300 °C |
7kw 7 kw |
单相220v Single-phase 220V |
硅碳棒 Silicon carbide rod |
S型 Type S |
MFX1400-40 MFX1400-40 |
400*300*300 400 * 300 * 300 |
1400℃ 1400 °C |
1300℃ 1300 °C |
12kw 12 kw |
三相380v Three-phase 380V |
硅碳棒 Silicon carbide rod |
S型 Type S |
MFX1400-50 MFX1400-50 |
500*400*400 500 * 400 * 400 |
1400℃ 1400 °C |
1300℃ 1300 °C |
15kw 15 kw |
三相380v Three-phase 380V |
硅碳棒 Silicon carbide rod |
S型 Type S |
MFX1400-60 Mfx1400-60 |
600*600*600 600 * 600 * 600 |
1400℃ 1400 °C |
1300℃ 1300 °C |
40kw 40 kw |
三相380v Three-phase 380V |
硅碳棒 Silicon carbide rod |
S型 Type S |
MFX1700-15 MFX1700-15 |
150*150*150 150 * 150 * 150 |
1700℃ 1700 °C |
1600℃ 1,600 °C |
2.5kw 2.5 kw |
单相220v Single-phase 220V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
MFX1700-30 MFX1700-30 |
300*200*200 300 * 200 * 200 |
1700℃ 1700 °C |
1600℃ 1,600 °C |
5kw 5 kw |
单相220v Single-phase 220V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
MFX1700-40 MFX1700-40 |
400*300*300 400 * 300 * 300 |
1700℃ 1700 °C |
1600℃ 1,600 °C |
16kw 16 kw |
两相380v Two-phase 380V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
MFX1700-50 MFX1700-50 |
500*400*400 500 * 400 * 400 |
1700℃ 1700 °C |
1600℃ 1,600 °C |
25kw 25 kw |
三相380v Three-phase 380V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
MFX1700-60 Mfx1700-60 |
600*600*600 600 * 600 * 600 |
1700℃ 1700 °C |
1600℃ 1,600 °C |
56kw 56 kw |
三相380v Three-phase 380V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
MFX1800-15 MFX1800-15 |
150*150*150 150 * 150 * 150 |
1800℃ 1800 °C |
1750℃ 1750 °C |
2.5kw 2.5 kw |
单相220v Single-phase 220V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
MFX1800-20 MFX1800-20 |
200*200*200 200 * 200 * 200 |
1800℃ 1800 °C |
1750℃ 1750 °C |
5kw 5 kw |
单相220v Single-phase 220V |
硅钼棒 Silicon molybdenum rod |
B型 Type B |
Furnace maintenance and precautions
1, the furnace maintenance and use of matters needing attention:
- When the electric furnace is used for the first time or is used again after being out of use for a long time, the furnace must be dried, otherwise the furnace chamber is easy to crack;
- Always keep clean, regularly check the electric furnace wiring is in good contact;
- The electric furnace is suitable for the following working conditions:
- A. For indoor use;
- B. elevation not exceeding 1000 m above sea level;
- C. ambient temperature in the + 5-40 °C range;
- D. the relative temperature of the surrounding environment does not exceed 85%
- E. There is no conductive dust around the furnace, explosive gas and can seriously damage the metal and insulation of corrosive gases.
When the electric furnace is used, the temperature of the furnace shall not exceed the rated temperature, so as not to damage the heating elements. Do not pour flammable liquids and dissolved metals into the furnace
In the working process, generally below 300 °C, heating rate should not be too fast, because just start heating furnace is cold, need to absorb a lot of heat; above 300 °C, heating rate can be within 10 degrees.
The furnace temperature should not exceed the rated temperature for a long time in order to avoid damage to heating elements. Do not pour flammable liquids and dissolved metals into the furnace.